Etatron metering pump DLX pH-Rx-CL/M
      
  
  Metering pump DLX pH-Rx-CL/M
- Diaphragm metering pump with microcontroller for pH, Rx (mV) and CI control
 - ON/OFF or proportional operation
 - LCD display
 - Power supply 230V standard, optional 12V, 24V or 120V (CLA/UL)
 - Measuring range 0 ÷ 14pH, -1000 ÷ +1400mV, 0 ÷ 2, 0 ÷ 20, 0 ÷ 200ppm
 - 4-20 mA output
 - Potential free relay alarm output
 - PT100 temperature input
 - Proximity Switch
 - Level alarm
 
| Type | max. Flow Rate | max. Pressure | 
 Pulse settings 
Imp./1' 
 | 
mL / Stroke | Power supply | 
 Power 
consumption (W) 
 | 
Current (A) | Weight (Kg) | 
|---|---|---|---|---|---|---|---|---|
| 1-15 | 1 L/H | 15 bar | 120 | 0,14 | 230V / 50-60 HZ | 37 | 0,16 | 2,3 | 
| 5-7 | 5 L/H | 7 bar | 120 | 0,69 | 37 | 0,16 | 2,3 | |
| 8-10 | 8 L/H | 10 bar | 120 | 1,11 | 58 | 0,25 | 2,9 | |
| 15-4 | 15 L/H | 4 bar | 120 | 2,08 | 58 | 0,25 | 2,9 | |
| 20-3 | 20 L/H | 3 bar | 120 | 2,6 | 58 | 0,25 | 2,9 | |
| 2-20 | 2 L/H | 20 bar | 120 | 0,28 | 58 | 0,25 | 2,9 | 
Downloads
Etatron_DLX_MA-AD_LDT_BA_DEU_2005.pdf (PDF, 2.0 MiB)
Etatron_DLX_MA-MB_LDT_BA_DEU_2014.pdf (PDF, 1.7 MiB)
Etatron_DLX_PH-RX-CL_LDT_BA_DEU_2014.pdf (PDF, 939.9 KiB)
Etatron_DLX_VFT-M_LDT_BA_DEU_2008.pdf (PDF, 1.5 MiB)
Etatron_DLX_CC-M_BA_FRA-ESP_2005.pdf (PDF, 1.6 MiB)
Etatron_DLX_CC-M_BA_ITA_ENG_2005.pdf (PDF, 2.5 MiB)
Etatron_DLX_CC-M_BA_POR-DEU_2005.pdf (PDF, 1.8 MiB)
Etatron_DLX_DLXB_MA_M_MB_BA_ITA_ENG_2005.pdf (PDF, 2.7 MiB)
Etatron_DLX_MA-AD_BA_MUL_DEU_2013.pdf (PDF, 3.7 MiB)
Etatron_DLX_MF-M_BA_DEU.pdf (PDF, 1.6 MiB)
Etatron_DLX_MF-M_BA_ITA_ENG_2013.pdf (PDF, 2.4 MiB)
Etatron_DLX_pH-RX-CL_BA_ITA_ENG_2013.pdf (PDF, 3.3 MiB)
Etatron_DLX_VFT-MBB_BA_ITA_ENG_2010.pdf (PDF, 2.8 MiB)
Etatron_DLX-DLXB_Info_MUL_2012.pdf (PDF, 1.1 MiB)